Loading...
YOUR ENERGY PROFILE.
This document contains the sizing of your future electrical installation, calculated based on your appliances.
Inventory:
To guarantee 0WH without damaging your bank (80% max discharge):
Minimum power required to recharge your consumption:
Maximum power (with 25% safety margin).
Use this professional reference table to select the correct gauge (mm²) for your cables. For 12V in a van, the maximum tolerated voltage drop is 3%. Always use multi-stranded flexible automotive wire.
| Current (A) | Round trip < 2m | Round trip 4m | Round trip 6m |
|---|---|---|---|
| 5A (LEDs, USB) | 1.5 mm² | 2.5 mm² | 4 mm² |
| 10A (Fridge, Pump) | 2.5 mm² | 4 mm² | 6 mm² |
| 20A (Heater) | 4 mm² | 10 mm² | 10 mm² |
| 50A (DC/DC Booster) | 10 mm² | 16 mm² | 25 mm² |
| 100A (Inverter) | 25 mm² | 35 mm² | 50 mm² |
The fuse protects the wire, not the appliance. Always place it as close to the power source as possible (battery or busbar).
0W
0 Ah
Lithium LiFePO4
Pompe, Leds, Frigo...
NON REQUI
SHOPPING LIST
Where to find this equipment? Here is the community-approved selection.
12V 6-way Fuse Box
Mandatory protection
Digital Multimeter
Test your connections
Heavy Duty Crimping Tool
For perfect lugs
Heat Shrink Tubing
Insulation and safety

Results based on a typical use case
| Appliance | Power | Usage/day | Wh/day |
|---|---|---|---|
| Compression fridge | 45W | 24h | 1080 |
| LED lighting | 20W | 4h | 80 |
| Water pump | 30W | 0.5h | 15 |
| Phone charging | 15W | 2h | 30 |
| Daily consumption | 1205 Wh | ||
Adjust these values with the calculator below
The devices that absolutely won't tolerate modified sine: CPAP/BiPAP machines (medical alert — some models shut down or deliver incorrect pressure), induction cooktops (won't even turn on), many laptop chargers (reduced lifespan, may not charge), laser printers, and some LED dimmers (flicker or buzz). I've personally killed a $200 Makita charger on modified sine — it ran hot for a week then the internal capacitor blew. Modified sine has exactly one advantage: efficiency. A cheap modified sine inverter converts 93-95% of DC to AC. A good pure sine manages 88-92%. That 3-5% difference means a modified sine wastes less power on the conversion itself. For a 100W continuous load, that's 3-5W saved — not enough to matter.
A pure sine wave inverter outputs a smooth, continuous wave that matches grid power exactly — 60Hz in the US, 50Hz in Europe, with a clean sinusoidal shape. This is what every electronic device is designed to receive. A modified sine wave is a stepped approximation — it jumps between positive voltage, zero, and negative voltage in sharp rectangular steps. The fundamental frequency is correct (50 or 60Hz), but the waveform is full of harmonics. Those harmonics cause audible buzzing in audio equipment, interfere with the timing circuits in CPAP machines, confuse the power factor correction in laptop chargers, and generate excess heat in motor windings. I can hear the difference: plug a speaker into modified sine and you get a faint 60Hz hum underneath the audio. Pure sine is silent.
The biggest mistake: buying the biggest inverter available "just in case." A 3000W inverter draws 15-25W of power just being turned on, even at zero load. Over 24 hours, that's 360-600Wh of parasitic draw — 25-40Ah from your battery doing absolutely nothing. I size the inverter for actual maximum simultaneous load plus 20% headroom. My typical loads: laptop charger (65W) + phone charger (15W) + LED TV (40W) = 120W simultaneous. A 300W inverter handles this perfectly. For occasional heavy loads — blender (600W), hair dryer (1200W on low), power tools (800W) — I run a 1500W pure sine. The only reason to go 2000W+ is regular induction cooking or running multiple heavy loads simultaneously. Common brands I trust: Victron Phoenix (premium, $300-500), Giandel (good mid-range, $150-250), AIMS (solid budget option, $120-200).
The cable between battery and inverter is the most critical wire in your entire system. A 2000W inverter at 12V pulls up to 180A at full load. That requires 35mm² cable for runs under 1.5 meters, or 50mm² for runs up to 3 meters. Use cable that's too thin and you'll see voltage drop, reduced inverter output, and heat buildup that can melt insulation. I keep the inverter as close to the battery as physically possible — ideally under 1 meter of cable. Fuse the positive cable with an ANL or MEGA fuse rated at 200-250A (for a 2000W/12V inverter). Mount the fuse within 30cm of the battery terminal. Ground the inverter chassis to the vehicle chassis with a short 6mm² bonding cable — this provides a safety ground for the AC outlets. And always install a remote on/off switch so you can kill the inverter from your living area without crawling to the battery box. The parasitic draw alone justifies never leaving it on when you don't need AC power.
Links marked with * are affiliate links. If a purchase is made through them, I receive a commission at no extra cost to you. The editorial selection and product evaluation are not influenced by commission rates. Your click helps fund this free tool.
$800ALLPOWERS