Results based on a typical use case
| Appliance | Power | Usage/day | Wh/day |
|---|---|---|---|
| Compression fridge | 45W | 24h | 1080 |
| LED lighting | 20W | 4h | 80 |
| Water pump | 30W | 0.5h | 15 |
| Phone charging | 15W | 2h | 30 |
| Daily consumption | 1205 Wh | ||
Adjust these values with the calculator below
YOUR ENERGY PROFILE.
This document contains the sizing of your future electrical installation, calculated based on your appliances.
Inventory:
To guarantee 0WH without damaging your bank (80% max discharge):
Minimum power required to recharge your consumption:
Maximum power (with 25% safety margin).
Use this professional reference table to select the correct gauge (mm²) for your cables. For 12V in a van, the maximum tolerated voltage drop is 3%. Always use multi-stranded flexible automotive wire.
| Current (A) | Round trip < 2m | Round trip 4m | Round trip 6m |
|---|---|---|---|
| 5A (LEDs, USB) | 1.5 mm² | 2.5 mm² | 4 mm² |
| 10A (Fridge, Pump) | 2.5 mm² | 4 mm² | 6 mm² |
| 20A (Heater) | 4 mm² | 10 mm² | 10 mm² |
| 50A (DC/DC Booster) | 10 mm² | 16 mm² | 25 mm² |
| 100A (Inverter) | 25 mm² | 35 mm² | 50 mm² |
The fuse protects the wire, not the appliance. Always place it as close to the power source as possible (battery or busbar).
0W
0 Ah
Lithium LiFePO4
Pompe, Leds, Frigo...
NON REQUI
SHOPPING LIST
Where to find this equipment? Here is the community-approved selection.
12V 6-way Fuse Box
Mandatory protection
Digital Multimeter
Test your connections
Heavy Duty Crimping Tool
For perfect lugs
Heat Shrink Tubing
Insulation and safety
Wiring matters more than people think. Connect both batteries with equal-length cables to a common bus bar — not daisy-chained (battery 1 → battery 2 → load). Daisy-chaining means battery 1 handles more current because it's closer to the load, leading to uneven wear. Equal-length cables ensure both batteries share the load 50/50. Use 25mm² (4 AWG) minimum for the interconnects on 200Ah systems, with a fuse on each battery's positive cable before they merge at the bus bar. I use 60A ANL fuses on each 100Ah battery — rated to protect the interconnect cable, not the battery capacity. One more thing: if you're paralleling LiFePO4 batteries with separate BMS units, make sure both BMS chips are compatible with parallel operation. Some cheaper BMS units fight each other — one cuts off while the other tries to compensate, creating a voltage oscillation that can trip both. SOK and BattleBorn are explicitly rated for parallel. Check the spec sheet for any others.